NOZZLE N3 — REINFORCEMENT PER UG-37REV B
Areq = d·tr·F + 2·tn·tr·F·(1 − fr1)UG-37(c)
= 12.750 × 0.281 × 1.0 + 2(0.330)(0.281)(1.0)(1 − 1.000)
Areq = 3.583 in²
Aavail = A1+A2+A3+A41+A5 = 4.112 in²
✓ PASS — A_avail > A_reqUG-37(d)